L404F1094 L404F1078 TBC2800A1000 BC1000A220F
BC1000A220U M7284A1004 R4343E1014 R4343D1017
C6097A2410 C6097A2110 ET401A Q7800A1005
Q624A1014 Q652B1014 S7800A1001 S7800Q1142
R7861A1026 R7849A1015 R7847B1072 ST7800A1005
RM789*1014 EC789*1010 C7061A1012 C7061A1020
C703*1023 Q270A1024 C7027A1023 C703*1064
129464N 129464M VE406*1000 VE402*1004
VE4020A1005 C7027A1049 M7284C1000 BXM4N
C7061F2001 R7849A1023 ST7800C1052 7616BR
S245B-12B16.0 Q625B1014 EC7895C1000 TBC1800A1001
KTBTF01 221818C 32000109-004 C6097A1228
V4046C1047 C6097B1036 VE4025B1136 R7847A1025
R7847A1033 R7849B1021 R7847A1082 S7810B1007
V4055D1001 V4015C1136 VR8205M1122 50017466-001
D06F-1/2A D06FH-1/2B VE4020C1094 V429*1015
V5097A1001 C7044A1006 V405*1007 C7009A1009
VE4065B1017 VE4080B1016 VE4050B1134 W7601A2006
ZT931 BC1000A0220F L404F1094 VE4050C1125
VE4065B3005 C6097A1079 R7600A1006 4320050
C7027A1049 C6097A0310 TBC2800A1000 V4043C1354
技术说明:
长*宽*高: 122 X 82 X 130.8 mm
输入电压: 220/230 VAC –15/+10%,50/60Hz
**功率: 9 VA
离子棒电缆长度: 75m(最长)
紫外电缆长度: 75m(最长)
火焰门槛初始设定值: 1μA(最小)
外壳材质: PC/ABS
黑色(底座)蓝色(外壳)
保护等级: IP54
环境温度: -20℃~+60℃
环境湿度: < 95%
运行寿命: 25万次(符合EN298标准)
驱动燃气阀的**电流: 1A;功率因数:1
驱动点火变压器的**电流:2A;功率因数:0.2
输出端子的**电流: 2A;交流电压:242V
UV 火检传感器型号: C7027A / C703* / C7044A
应用:霍尼韦尔TBC2800系列是为工业和商业燃烧系统研发的高性能烧嘴控制器,适用于各种燃气燃料的燃烧控制。
特点:集成离子棒和UV火检方式,可通过设定切换
六种运行参数集成可选配置
24小时连续运行(UV除外) ,运行寿命超过25万次
IP54保护等级,适合现场或机柜安装
多功能按键组合,LED状态指示灯组合运行状态、故障信息和火焰强度实时显示
远程或现场复位
可调节的火焰门槛值
符合欧洲EN298标准
主要技术参数:长X宽X高:122.5X82X131。2mm
输入电压:220 V
**功率:9VA
离子棒电缆最长长度: 75m
紫外电缆最长长度:75米
外壳材质:PC/A3S
黑色(底座)
蓝色(外壳)
保护等级:IP 54
环境温度:-20°C~+60°C |