麦提斯(北京)电力科技有限公司 ,Copper wire reactor/ Copper foil reactor 分为铜线式电抗、铜箔式电抗 Good performance of suppression to high harmonic in electricity grid system 抑制电网中高次谐波 Good performance of suppression to over currency and over voltage 限制合闸涌流及操作过电压 Improve power factor and curve of voltage 改善系统电压波形,提高电网功率因数 To help to arc extinguishing 有利于接触器的灭弧 To pretect system 保护设备正常运行 To close temperature protector 常闭温度保护器 HV Series dry-type reactor高压串联电抗器 Good performance of suppression to over currency and over voltage 限制合闸涌流及操作过电压 Improve power factor and curve of voltage 改善系统电压波形,提高电网功率因数 干式铁芯高压串联电抗器用于6-35KV电力系统与高压电容器组相串联 To help to arc extinguishing 有利于接触器的灭弧 To pretect system 保护设备正常运行 低压电抗器型号 MTRE480W10T-7C MTRE480W15T-7C MTRE480W20T-7C MTRE480W25T-7C MTRE480W30T-7C MTRE480W35T-7C MTRE480W40T-7C MTRE480W45T-7C MTRE480W50T-7C MTRE480W55T-7C MTRE480W60T-7C MTRE480W65T-7C MTRE480W70T-7C 高压电抗器型号 MTHRE12W150T-6C MTHRE12W200T-6C MTHRE12W300T-6C MTHRE12W350T-6C MTHRE12W400T-6C MTHRE12W450T-6C MTHRE12W500T-6C MTHRE12W600T-6C MTHRE12W700T-6C MTHRE12W800T-6C MTHRE12W900T-6C MTHRE12W1000T-6C MTHRE12W1200T-6C MTHRE12W1500T-6C MTHRE12W1800T-6C MTRE type 电抗器 Rated voltage 额定电压:单相250V、280V三相440/480/ 525/ 800VAC Voltage test 电压测试:4K VAC/minute, T-C and T-T 端子对地、端子对端子加电压4000VAC,持续一分钟Temperature increasing 温升: less than 120°C at rated frequency by insistence test 在持续测试纟下,麦提斯(北京)电力科技有限公司,在额定率丬下,专业电抗器,温度不高于120度 Insulation level 绝缘等级:H class (180°C) H class (180°C) Noise 噪音:less than 48dB under normal working condition 小于48dBtest distance is 1 meter away from reactor 测试距离为一米 Insulation paper used 绝缘纸 : good inflaming retarding and dielectric property 良好的阻燃和介电性能纸 Standard 标准:According to IEC 289 and GB/T 10 HV Series dry-type reactor高压串联电抗器 Rated voltage 额定电压:可用于6KV、7.2KV、10KV、11KV、12KV、35KV场合 Voltage test 电压测试:外施耐压:对地、对相施加42KV电压一分钟,无击穿、闪络现象 Temperature increasing 温升:less than 120°C at rated frequency by insistence test 在持续测试下,在额定频率下,专业电抗器,温度不高于120度 Insulation level 绝缘等级:H class (180°C) Noise 噪音:less than 30dB under normal working condition 小于30dBtest distance is 1 meter away from reactor 测试距离为一米 Insulation paper used 绝缘纸:good inflaming retarding and dielectric property 良好的阻燃和介电性能纸 Standard 标准:According to JB/T5346-1998 电抗器的安装 Application 安装地点:Indoor, well-ventilated 室内,良好对流通风 Maximum Altitude **海拔:1000 Meters above sea level 海拔2000米 Enviroment 环境要求:None combustible and explosive goods nearby 安装点周围不可有影响绝缘性能的物质以及易燃易爆等物品 Operating Temperature 工作温度:'-20°C to +40°C, with Natural convection cooling **-20度,**40度 average daily temperature is less than 30°C 平均温度30度 Space the reactor apart 电抗之间距离:>5cm to horizontal direction 水平距离5厘米以上 >12cm to vertical direction 垂直距离12厘米以上
.麦提斯(北京)电力科技___专业电抗器 |