Î÷ÃÅ×ÓPLC¿¨¼þ6ES7322-1HF01-0AA0
Æ·ÅÆ£ºsiemens/Î÷ÃÅ×Ó ²úÆ·¹æ¸ñ£ºÈ«ÐÂÔ×°
ÉϺ£èî³Ê¹¤Òµ×Ô¶¯»¯É豸ÓÐÏÞ¹«Ë¾
ÁªÏµÈË£ºÀîÏô
24СʱÏúÊÛ¼¼Êõ·þÎñÈÈÏߣº138-1888-0443£¨Î¢ÐÅͬ²½£©
Q Q£º1123522411
ͨ¹ýÓ²¼þºÍÈí¼þÕìÌýµÄ·½·¨£¬·ÖÎöPLCÄÚ²¿¹ÌÓеÄPPIͨѶÐÒ飬ȻºóÉÏλ»ú²ÉÓÃVB±à³Ì£¬×ñÑPPIͨѶÐÒ飬¶ÁдPLCÊý¾Ý£¬ÊµÏÖÈË»ú²Ù×÷ÈÎÎñ¡£ÕâÖÖͨѶ·½·¨£¬ÓëÒ»°ãµÄ×ÔÓÉͨѶÐÒéÏà±È£¬Ê¡ÂÔÁËPLCµÄͨѶ³ÌÐò±àд£¬Ö»Ðè±àдÉÏλ»úµÄͨѶ³ÌÐò×ÊÔ´
S7-226µÄ±à³Ì¿ÚÎïÀí²ãΪRS-485½á¹¹£¬SIEMENSÌṩMicroWinÈí¼þ£¬²ÉÓõÄÊÇPPI(Point to Point)ÐÒ飬¿ÉÒÔÓÃÀ´´«Êä¡¢µ÷ÊÔPLC³ÌÐò¡£ÔÚÏÖ³¡Ó¦ÓÃÖУ¬µ±ÐèÒªPLCÓëÉÏλ»úͨѶʱ£¬½Ï¶àµÄʹÓÃ×Ô¶¨ÒåÐÒéÓëÉÏλ»úͨѶ¡£ÔÚÕâÖÖͨѶ·½Ê½ÖУ¬ÐèÒª±à³ÌÕßÊ×Ïȶ¨Òå×Ô¼ºµÄ×ÔÓÉͨѶ¸ñʽ£¬ÔÚPLCÖбàд´úÂ룬ÀûÓÃÖжϷ½Ê½¿ØÖÆͨѶ¶Ë¿ÚµÄÊý¾ÝÊÕ·¢¡£²ÉÓÃÕâÖÖ·½Ê½£¬PLC±à³Ìµ÷ÊÔ½ÏΪ·³Ëö£¬Õ¼ÓÃPLCµÄÈí¼þÖжϺʹúÂë×ÊÔ´£¬¶øÇÒµ±PLCµÄͨѶ¿Ú¶¨ÒåΪ×ÔÓÉͨѶ¿Úʱ£¬PLCµÄ±à³ÌÈí¼þÎÞ·¨¶ÔPLC½øÐмà¿Ø£¬¸øPLC³ÌÐòµ÷ÊÔ´øÀ´²»±ã¡£
SIEMENS S7-200PLCµÄ±à³ÌͨѶ½Ó¿Ú£¬ÄÚ²¿¹Ì»¯µÄͨѶÐÒéΪPPIÐÒ飬Èç¹ûÉÏλ»ú×ñÑPPIÐÒéÀ´¶ÁдPLC£¬¾Í¿ÉÒÔÊ¡ÂÔ±àдPLCµÄͨѶ´úÂë¡£ÈçºÎ»ñµÃPPIÐÒ飿¿ÉÒÔÔÚPLCµÄ±à³ÌÈí¼þ¶ÁдPLCÊý¾Ýʱ£¬ÀûÓõÚÈý¸ö´®¿ÚÕìÌýPLCµÄͨѶÊý¾Ý£¬»òÕßÀûÓÃÈí¼þ·½·¨£¬½ØÈ¡ÒѾ´ò¿ªÇÒÕýÔÚͨѶµÄ¶Ë¿ÚµÄÊý¾Ý£¬È»ºó¹éÄÉ×ܽᣬ½âÎö³öPPIÐÒéµÄÊý¾Ý¶Áд±¨ÎÄ¡£ÕâÑù£¬ÉÏλ»ú×ñÑPPIÐÒ飬¾Í¿ÉÒÔ±ãÀûµÄ¶ÁдPLCÄÚ²¿µÄÊý¾Ý£¬ÊµÏÖÉÏλ»úµÄÈË»ú²Ù×÷¹¦ÄÜ¡£
Èí¼þÉè¼Æ
ϵͳÖвâ¿ØÈÎÎñÓÉSIEMENS S7-226PLCÍê³É£¬PLC²ÉÓÃÑ»·É¨Ã跽ʽ¹¤×÷£¬µ±¶¨Ê±Ê±¼äµ½Ê±£¬Ö´ÐÐÊý¾Ý²É¼¯»òPID¿ØÖÆÈÎÎñ£¬Íê³ÉÏÖ³¡µÄÐźſØÖÆ¡£¼ÆËã»úµÄ¼à¿ØÈí¼þ²ÉÓÃVB±àÖÆ£¬ÀûÓÃMSComm¿Ø¼þÍê³É´®¿ÚÊý¾ÝͨѶ£¬Í¨Ñ¶×ñѵÄÐÒéΪPPIÐÒé¡£
PPIÐÒé
Î÷ÃÅ×ÓµÄPPI£¨Point to Point£©Í¨Ñ¶ÐÒé²ÉÓÃÖ÷´ÓʽµÄͨѶ·½Ê½£¬Ò»´Î¶Áд²Ù×÷µÄ²½Öè°üÀ¨£ºÊ×ÏÈÉÏλ»ú·¢³ö¶ÁдÃüÁPLC×÷³ö½ÓÊÕÕýÈ·µÄÏìÓ¦£¬ÉÏλ»ú½Óµ½´ËÏìÓ¦Ôò·¢³öÈ·ÈÏÉêÇëÃüÁPLCÔòÍê³ÉÕýÈ·µÄ¶ÁдÏìÓ¦£¬»ØÓ¦¸øÉÏλ»úÊý¾Ý¡£ÕâÑùÊÕ·¢Á½´ÎÊý¾Ý£¬Íê³ÉÒ»´ÎÊý¾ÝµÄ¶Áд[5]¡£
ÆäͨѶÊý¾Ý±¨Îĸñʽ´óÖÂÓÐÒÔϼ¸Àࣺ
1¡¢¶ÁдÉêÇëµÄÊý¾Ý¸ñʽÈçÏ£º
SD LE LER SD DA SA FC DASP SSAP DU FCS ED
SD:(Start Delimiter)¿ªÊ¼¶¨½ç·û(68H)
LE:£¨Length£©±¨ÎÄÊý¾Ý³¤¶È
LER:£¨Repeated Length£©Öظ´Êý¾Ý³¤¶È
SD: (Start Delimiter)¿ªÊ¼¶¨½ç·û(68H)
SA:£¨Source Address£©Ô´µØÖ·£¬Ö¸¸ÃµØÖ·µÄÖ¸Õ룬ΪµØÖ·Öµ³ËÒÔ8
DA:£¨Destination Address£©Ä¿±êµØÖ·£¬Ö¸¸ÃµØÖ·µÄÖ¸Õ룬ΪµØÖ·Öµ³ËÒÔ8
FC:£¨Function Code£©¹¦ÄÜÂë
DSAP:£¨Destination Service Access Point£©Ä¿µÄ·þÎñ´æÈ¡µã
SSAP:£¨Source Service Access Point£©Ô´·þÎñ´æÈ¡µã
DU:£¨Data Unit£©Êý¾Ýµ¥Ôª
FCS:£¨Frame Check Sequence£©Ð£ÑéÂë
ED:£¨End Delimiter£©½áÊø·Ö½ç·û£¨16H£©
±¨ÎÄÊý¾Ý³¤¶ÈºÍÖظ´Êý¾Ý³¤¶ÈΪ×ÔDAÖÁDUµÄÊý¾Ý³¤¶È£¬Ð£ÑéÂëΪDAÖÁDUÊý¾ÝµÄºÍУÑ飬ֻȡÆäÖеÄÄ©×Ö½ÚÖµ¡£
ÔÚ¶ÁдPLCµÄ±äÁ¿Êý¾ÝÖУ¬¶ÁÊý¾ÝµÄ¹¦ÄÜÂëΪ 6CH£¬Ð´Êý¾ÝµÄ¹¦ÄÜÂëΪ 7CH¡£
2¡¢PLC½ÓÊÕµ½¶ÁдÃüÁУÑéºóÕýÈ·£¬·µ»ØµÄÊý¾Ý¸ñʽΪ E5H
3¡¢È·È϶ÁдÃüÁîµÄÊý¾Ý¸ñʽΪ£º
SD SA DA FC FCS ED
ÆäÖÐSDΪÆðʼ·û£¬Îª10H
SAΪÊý¾ÝÔ´µØÖ·
DAΪĿµÄµØÖ·
FCΪ¹¦ÄÜÂ룬ȡ5CH
FCSΪSA+DA+FCµÄºÍµÄÄ©×Ö½Ú
EDΪ½áÊø·û£¬È¡16H
PPIÐÒéµÄÈí¼þ±àÖÆ
ÔÚ²ÉÓÃÉÏλ»úÓëPLCͨѶʱ£¬ÉÏλ»ú²ÉÓÃVB±à³Ì£¬¼ÆËã»ú²ÉÓÃPPIµçÀ»òÆÕͨµÄ485´®¿Ú¿¨ÓëPLCµÄ±à³Ì¿ÚÁ¬½Ó£¬Í¨Ñ¶ÏµÍ³²ÉÓÃÖ÷´Ó½á¹¹£¬ÉÏλ»ú×ñÑPPIÐÒé¸ñʽ£¬·¢³ö¶ÁдÉêÇ룬PLC·µ»ØÏàÓ¦µÄÊý¾Ý¡£³ÌÐòʵÏÖÈçÏ£º
1¡¢´®¿Ú³õʼ»¯³ÌÐò£º
MSComm1.CommPort = 1
MSComm1.Settings = "9600,e,8,1"
MSComm1.InputLen = 0
MSComm1.RThreshold = 1
MSComm1.InputMode = comInputModeBinary
PPIÐÒ鶨Òå´®¿ÚΪÒÔ¶þ½øÖÆÐÎʽÊÕ·¢Êý¾Ý£¬ÕâÑù±¨ÎĵÄͨѶЧÂʱÈASCIIÂë¸ß¡£
2¡¢´®¿Ú¶ÁÈ¡Êý¾Ý³ÌÐò£¬ÒÔ¶ÁÈ¡VB100Êý¾Ýµ¥ÔªÎªÀý£º
Dim Str_Read(0 To 32) ¡®¶¨Òå·¢Ë͵ÄÊý¾ÝΪ×Ö½ÚΪԪËصÄÊý×é¡£
Str_ Read (32) = &H16 ¡®ÏàÓ¦µÄÊý×éÔªËظ³Öµ£¬°´ÕÕÒÔϸñʽ£º
Str_ Read (29) = (100*8) \ 256 ¡®µØַΪָÕëÖµ£¬ÏÈÈ¡¸ßλµØÖ·Ö¸Õë
Str_ Read (30) = (100*8) Mod 256 ¡®È¡µÍλµØÖ·Ö¸Õë
Str_ Read (24) = 1 ¡®¶ÁÈ¡µÄÊý¾Ý³¤¶È£¨ByteµÄ¸öÊý£©
For I=4 to 30
Temp_FCS = Temp_FCS + Str_Read(i)
Next I
Str_Read(31)= Temp_FCS Mod 256 ¡®¼ÆËãFCSУÑéÂ룬ÆäËüÊý×éÔªËظ³ÖµÊ¡ÂÔ¡£
68 1B 1B 68 2 0 6C 32 1 0 0 0 0 0 E 0 0 4 1 12 A 10 2 0 1 0 1 84 0 3 20 8B 16
PLC·µ»ØÊý¾Ý E5 ºó£¬È·È϶ÁÈ¡ÃüÁ·¢ËÍÒÔÏÂÊý¾Ý£º
10 2 0 5C 5E 16
È»ºóÉÏλ»úVB³ÌÐò½ÓÊܵ½ÒÔÏÂÊý¾Ý£º
68 16 16 68 0 2 8 32 3 0 0 0 0 0 2 0 5 0 0 4 1 FF 4 0 8 22 78 16
Ê×ÏÈʶ±ðÄ¿±êµØÖ·ºÍÔ´µØÖ·£¬È·ÈÏÊÇÕâ´ÎÉêÇëµÄ·µ»ØÊý¾Ý£¬È»ºó¾¹ýУÑé¼ì²é£¬ÕýÈ·ºó½âÎö³öµÚ26ºÅÊý¾Ý£¨&H22£©¼´ÎªVB100×Ö½ÚµÄÊý¾Ý¡£
3¡¢´®¿ÚдÈëÊý¾Ý³ÌÐò£¬ÒÔдVB100Êý¾Ýµ¥ÔªÎªÀý£º
Dim Str_Write(0 To 37) ¡®¶¨Òå·¢Ë͵ÄÊý¾ÝΪ×Ö½ÚΪԪËصÄÊý×é¡£
Str_Write (37) = &H16 ¡®ÏàÓ¦µÄÊý×éÔªËظ³Öµ£¬°´ÕÕÒÔϸñʽ
Str_Write (35) = &H10 ¡®ÒªÐ´ÈëµÄÊý¾ÝÖµ
68 20 20 68 2 0 7C 32 1 0 0 0 0 0 E 0 5 5 1 12 A 10 2 0 1 0 1 84 0 3 20 0 4 0 8 C B9 16
PLC·µ»ØÊý¾Ý E5 ºó£¬È·ÈÏдÈëÃüÁ·¢ËÍÒÔÏÂÊý¾Ý£º
10 2 0 5C 5E 16
È»ºóÉÏλ»úVB³ÌÐò½ÓÊܵ½ÒÔÏÂÊý¾Ý£º
68 12 12 68 0 2 8 32 3 0 0 0 0 0 2 0 1 0 0 5 1 FF 47 16
ÕâÊÇPLCÕýÈ·½ÓÊÕ²¢Ð´ÈëÐÅÏ¢µÄ·µ»ØÊý¾Ý¡£
4¡¢´®¿Ú½ÓÊÕ³ÌÐò£º
ÔÚÊý¾Ý½ÓÊÕ³ÌÐòÖУ¬ÀûÓÃVBÖÐMSComm¿Ø¼þ£¬Ò»´Î½ÓÊÕ»º³åÇøÖеÄÈ«²¿Êý¾Ý£¬´æ·Åµ½Êý×éÐÎʽµÄÔÝ´æµ¥ÔªÖУ¬È»ºó·ÖÎöÿ¸öÔªËصÄÖµ£¬µÃµ½¶ÁдµÄÊý¾Ý¡£
Dim RCV_Array() As Byte
Dim Dis_Array As String
Dim RCV_Len As Long
RCV_Array = MSComm1.Input ¡®È¡³ö´®¿Ú½ÓÊÕ»º³åÆ÷µÄÊý¾Ý¡£
RCV_Len = UBound(RCV_Array)
ReDim Temp(0 To UBound(RCV_Array))
For i = 0 To RCV_Len
Dis_Array = Dis_Array & Hex(RCV_Array (i)) & " "
Next i
Text1.Text = Dis_Array ¡®½ÓÊÕµ½µÄÊý¾ÝËÍÏÔʾ¡£
ÔÚ³ÌÐòµÄ¶Áд¹ý³ÌÖУ¬Ò»´Î**¿ÉÒÔ¶Áд222¸ö×Ö½Ú£¬Ä¿Ç°¸ø³öµÄÊý¾Ý¶ÁдΪÕûÊý¸ñʽ¡£
Êý¾ÝÀàÐÍ Str_ Read£¨27£©
S 04H
SM 05H
I 81H
Q 82H
M 83H
V 84H
ÒÔÉϳÌÐò£¬ÊÇÒÔ¶ÁдPLCµÄV±äÁ¿ÇøΪÀý£¬ÀûÓÃPPIÐÒ黹¿ÉÒÔ¶ÁдS7-200PLCÖеĸ÷ÖÖÀàÐÍÊý¾Ý£¬°üÀ¨I¡¢Q¡¢SM¡¢M¡¢V¡¢T¡¢C¡¢SµÈÊý¾ÝÀàÐÍ£¬Äܹ»Ö±½Ó¶Á³öÒÔÉϱäÁ¿ÖеÄλ¡¢×Ö½Ú¡¢×Ö¡¢Ë«×ֵȣ¬ÆäÖжÁλ±äÁ¿Ê±£¬ÊǶÁÈ¡¸ÃλËùÔÚµÄ×Ö½ÚÖµ£¬È»ºóÉÏλ»ú×Ô¶¯Ê¶±ð³ö¸ÃλµÄÖµ¡£°´ÕÕ¶ÁдµÄÊý¾ÝÀàÐÍ£¬ÆäÖÐStr_ Read£¨27£©µÄÖµ¸÷²»Í¬£º
ÔÚ¿ØÖÆϵͳÖУ¬PLCÓëÉÏλ¼ÆËã»úµÄͨѶ£¬²ÉÓÃÁËPPIͨѶÐÒ飬ÉÏλ»úÿ0.5ÃëÑ»·¶Áдһ´ÎPLC¡£PLC±à³Ìʱ£¬½«Òª¶ÁÈ¡µÄ¼ì²âÖµ¡¢Êä³öÖµµÈÊý¾Ý£¬´æ·ÅÔÚPLCµÄÒ»¸öÁ¬ÐøµÄ±äÁ¿ÇøÖУ¬µ±ÉÏλ»ú¶ÁÈ¡PLCµÄÊý¾Ýʱ£¬¾Í¿ÉÒÔÒ»´Î¶Á³öÕâ×éÁ¬ÐøµÄÊý¾Ý£¬¼õÉÙÊý¾ÝµÄ·Ö´ÎƵ·±¶ÁÈ¡¡£µ±ÐÞ¸ÄÉ趨ֵµÈÊý¾Ýʱ£¬½øÐÐдÊý¾ÝµÄͨѶ²Ù×÷¡£
×ÊѶÀ´Ô´£º13818880443
|